This guide is useful for electricians and door entry installers in helping them put together the right list of components required for a wide variety of doors. These components are compatible with our range of IP Door Intercoms and provide the user with various options for access control including RFID readers and keypads, magnetic locks and strike locks.
- Magnetic locks for internal doors
- Magnetic locks for external doors
- Magnetic locks for glass doors
- Electric strike locks (Euro style locks)
- Dead bolt locks
- ANSI style locks
- Double action locks for swing doors
Magnetic locks for internal doors
Not suitable for glass doors
Part Number | Description | RRP | |
---|---|---|---|
PV-PSU12-1SM | Power supply - battery backup enabled (12v at 1 amp) | £51.25 | |
EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button, surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-C3S11 | 300KG Magnetic lock | £55.90 | |
PV-300ZL | 300KG/400KG Magnetic lock ZL mounting brackets | £26.18 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 | |
PV-FM | 60cm door loop cable housing (optional) | £14.09 |
In the event of a power cut, the Mag Lock will release immediately. PV-B60 battery can be used to provide power to the Mag lock in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Magnetic locks for external doors
Not suitable for glass doors
Part Number | Description | RRP | |
---|---|---|---|
PV-PSU12-1SM | Power supply - battery backup enabled (12v at 1 amp) | £51.25 | |
EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button, surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-C3S11 | 300KG Magnetic lock | £55.90 | |
PV-300ZL | 300KG/400KG Magnetic lock ZL mounting brackets | £26.18 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 | |
PV-FM | 60cm door loop cable housing (optional) | £14.09 |
In the event of a power cut, the Mag Lock will release immediately. PV-B60 battery can be used to provide power to the Mag lock in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Magnetic locks for glass doors
Suitable for glass doors ONLY
Part Number | Description | RRP | |
---|---|---|---|
PV-PSU12-1SM | Power supply - battery backup enabled (12v at 1 amp) | £51.25 | |
EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button, surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-C3S11 | 300KG Magnetic lock | £55.90 | |
PV-300ZL | 300KG/400KG Magnetic lock ZL mounting brackets | £26.18 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 | |
PV-FM | 60cm door loop cable housing (optional) | £14.09 |
In the event of a power cut, the Mag Lock will release immediately. PV-B60 battery can be used to provide power to the Mag lock in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Electric strike locks (Euro style locks)
Not suitable for PVC doors
Part Number | Description | RRP | |
---|---|---|---|
PV-EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button - surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-GAERI | Fail safe strike kit 12v AC/DC, flush and surface, adjustable jaw. Non-symmetrical (Lock can be powered using the 12V output from the door intercom) | £29.99 | |
gaer-wiring | Wiring loom for GAER door release for PoE powered systems. | £50.00 |
Optional Powering Kit
PV-PSU12-1SM | Power supply (12v at 1 amp) – (Optional - Only required if no POE) | £51.25 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 |
Lock In Fail Safe Mode:
In the event of a power cut, the Strike Lock will release immediately. PV-B60 battery can be used in case customer want to keep door locked in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Lock in Fail Secure Mode
In the event of a power cut, the Strike Lock will stay locked. PV-B60 battery is required to make sure lock is powered and user can exit the building using Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Dead bolt locks
Part Number | Description | RRP | |
---|---|---|---|
PV-EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button - surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-DBR-310FS | Dead-bolt release, fail safe, monitored | £108.93 | |
gaer-wiring | Wiring loom for GAER door release for PoE powered systems. | £50.00 |
Optional Powering Kit
PV-PSU12-1SM | Power supply (12v at 1 amp) – (Optional - Only required if no POE) | £51.25 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 |
In the event of a power cut, the Strike Lock will release immediately. PV-B60 battery can be used in case customer want to keep door locked in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Lock in Fail Secure Mode
In the event of a power cut, the Strike Lock will stay locked. PV-B60 battery is required to make sure lock is powered and user can exit the building using Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
ANSI style locks
Not suitable for PVC doors
Part Number | Description | RRP | |
---|---|---|---|
PV-EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button, surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
PV-ARU | ANSI style release, fail secure/fail safe, 12vdc/250ma (Lock can be powered using the 12V output from door intercom) | £45.00 | |
gaer-wiring | Wiring loom for gaer door release for PoE powered systems. | £50.00 |
Optional Powering Kit
Part Number | Description | RRP | |
---|---|---|---|
PV-PSU12-1SM | Power supply (12v at 1 amp) – (Optional - Only required if no POE) | £51.25 | |
PV-B60 | 12v 7A/H battery (optional) | £28.75 |
Lock In Fail Safe Mode
In the event of a power cut, the Strike Lock will release immediately. PV-B60 battery can be used in case customer want to keep door locked in the event of power failure. During normal operation user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Lock in Fail Secure Mode
In the event of a power cut, the Strike Lock will stay locked. PV-B60 battery is required to make sure lock is powered and user can exit the building using Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Double action locks for swing doors
Suitable for double swing doors ONLY
Part Number | Description | RRP | |
---|---|---|---|
PV-SDA25I | Double Action Fail safe, 25mm backset | £113.30 | |
PV-EM201GDM | Double pole resettable emergency door release (multiple use) | £17.88 | |
PV-RTE0001S | Plastic exit button, surface mount | £12.74 | |
PV-VHLD | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For ProTalk systems ONLY) | £25.25 | |
9159010 | Security relay switch- exit switch delay unit for 12v fail-safe locks. (For 2N systems ONLY) | £170.13 | |
gaer-wiring | Wiring loom for gaer door release for PoE powered systems. | £50.00 |
Optional powering kit
Part Number | Description | RRP | |
---|---|---|---|
PV-PSU12-1SM | Power supply (12v at 1 amp) –(Optional -Only required if no POE) | £51.25 | |
PV-B60 | 12v 7A/H battery | £28.75 |
Lock In Fail Safe Mode
In the event of a power cut, the Strike Lock will release immediately. PV-B60 battery can be used in case the user wants to keep the door locked in the event of power failure. During normal operation, user would press the Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.
Lock in Fail Secure Mode
In the event of a power cut, the Strike Lock will stay locked. PV-B60 battery is required to make sure the lock is powered and user can exit the building using Push to Exit Button or in the event of an emergency, the Emergency Break Glass unit to exit the building.